Unipulse F701 basic weighing controller

Unipulse F701 basic weighing controllerF701 is a general-purpose weighing controller that is compatible with all weighing systems. This is a practical device excellent in cost effectiveness, which is

  • Brand: Unipulse
  • Model: F701

Unipulse F701 basic weighing controller

F701 is a general-purpose weighing controller that is compatible with all weighing systems. This is a practical device excellent in cost effectiveness, which is equipped with the final discharge function allowing high-accuracy feeding and discharging weighing control, the weighing sequence function essential to hopper and packing scales, and the interface connectable to various peripherals such as RS-232C and BCD output.

F701-1.jpg

ANALOG SECTION
Excitation voltage10V DC ±5%, Output current; within 120mA, remote sense type (Up to 4 loadcells at 350Ω are parallel-connectable.)
Zero adjustment range0 - 1.5mV/V for HI gain
0 - 3.0mV/V for LO gain (digital adjustment) 
Input of approx. 0.5mV/V or 1.0mV/V, Selectable adjust to zero [by dip switch on the rear panel]
Gain adjustment range2 stages of gain selectable according to the output of loadcell [by dip switch on the rear panel]
0.5 - 1.5mV/V for HI gain, 1.0 - 3.0mV/V for LO gain (digital adjustment)
Min. input sensitivity0.5μV / count
AccuracyNon-linearity: within 0.01%/FS
Zero drift: within 0.2μV/°C RTI (Typ: 0.15μV/°C) 
Gain drift: within 15ppm/°C (Typ: 7ppm/°C)
Noise: within 0.1μVp-p RTI (0.1 - 10 Hz)
Analog filterBessel low-pass filter (-12dB/oct.) selectable from 2, 4, 6, 8 Hz
A/D converterSpeed: 100 times/sec
Resolution: 16 bit
Min. display resolution1/10000
Secondary calibrationCalibration can be carried out without an actual load by connecting a resistor to one of the bridges of a loadcell.
SETTING SECTION
Setting method? Keyboard operation (membrane switch with a key click buzzer) 
? External setting is available by installing a setting point option or RS-232C option
Setting value storage? Initial set values: NOV RAM (Non-volatile RAM)
? Other set values: C-MOS RAM with backup of a lithium battery (Effective for more than 7 years depending on usage conditions and storage environment.)
Setting value protectionSetting operation can be locked to prevent unauthorized modifications of default values and calibration by malfunction
 
INPUT/OUTPUT SECTION
External output signalTransistor’s open collector output (Emitter = COM terminal); Output is LO when transistor is ON (Near zero, SP1, SP2, SP3, go or comp, over, under, high limit, Low limit, stable, weight alarm or error, run)
External input signalON when shorted to COM terminal by TTL-level relay, switch, transistor, or open collector output. (Feed / discharge, tare ON, tare OFF, zero, gross / net, hold or judgment, start, stop) (Drive current: 10mA or less)
Output Conditions- SP1: Net weight >= final weight-SP1
- SP2: Net weight >= final weight-before final
- SP3: Net weight >= final weight-FF
- Under: Net weight < final weight-underweight
- Over: Net weight > final weight-overweight
- Go: Final weight+overweight >= netweight >= final weight-underweight
Interface
  • ? SIF:

  • 2-wire type serial interface (standard); Interface to link with Unipulse printer or external display

  •  

  • ? SPI:

  • Interface for set-point units (Optional); Interface to enter various set values via digital switches

  •  

  • ? BCO:

  • BCD parallel data output interface (Optional): Parallel interface to transmit weight data to a printer, external display, PC or sequencer.

  •  

  • ? 232:

  • RS-232C communication interface (Optional): Write (change) / read weight data, various statuses and setting values from a PC or sequencer.

  •  

  • ? 485:

  • RS-485 communication interface (Optional): Allows longer-distance communication than RS-232C. ID numbers are set, and multiple units of F701 are parallel-connectable.

  •  

  • ? DAC:

  • D/A converter interface (Optional); Interface to convert weight data to current signal and output it.

 
DISPLAY SECTION
Display unitNumerical display (7 digits) with a character height of 18.5 mm by fluorescent display tube
Display value5 digits, Minus sign displayed on most significant digit
Scale capacity5-digit numerical values
Min. scale division1 to 100
Decimal pointSelectable from 0, 0.0, 0.00, 0.000 (with zero blanking function)
Over-scale displayInput of A/D converter overflow, Net weight over the set net value, scale capacity + 9 scale divisions, Gross weight over the set gross weight
Center zeroTrue zero point or the center of each value is displayed.
Unit displaySelectable from t, kg, g, N, lb, none
Status displaySP3, SP2, SP1, LOCK, ZT, ZALM, STAB, TARE, NET, GROSS, HI LIM, HI, GO, LO, LO LIM, HOLD, NZ
 
GENERAL SPECIFICATIONS
Power supply voltage85 - 110V, 102 - 132V, 170 - 220V, 187 - 242V AC (Please specify when ordering), 50/60 Hz
Power consumptionApprox. 15VA
Operating conditionsTemperature: Working temperature range -10°C - +40°C; Storage temperature range -20 - +85°C
Humidity: 85% RH or less (non-condensing)
External dimensions192 (W) x 96 (H) x 160 (D) [mm] (protruding parts not included)
Panel cutout dimensions186(+2 / -0) (W) x 92 (+1 / -0)(H) mm  (protruding parts not included)
*Installation panel thickness: 1.6 mm or more
WeightApprox. 2.2 kg
 
ACCESSORIES
AC input cord (2m)1
Spare fuse (1A)1
Loadcell input connector1
Control signal I/O connector1
Flathead screwdriver1
Operation Manual1
Set point unit connector (when set point unit option is installed)1
BCD output connector (when BCD output option is installed)1
D/A converter connector (when D/A converter option is installed)1
  
Drum Filling Machine

Option

ModelDescription
SPISet point unit interface
BCOBCD parallel data output interface
232RS-232C communication interface
485RS-485 communication interface
DACD/A converter interface
  
Drum Filling Machine

Optional accessories

ModelDescription
E780Set point unit
LB01-NHLithium battery (with NH connector)
CAAC2P-P2AC input cord 2 m
CAAC3P-CEE7/7-P1.5AC input cord (250V withstand voltage) 1.5 m
CN3P-2P3P-2P conversion plug for AC input cord
CA4131(6-core) cable with JR connector at one end (cable end is separated) 3 m
CA4230JR-PRC conversion relay (6-core) cable 0.3 m
CA4311JR-PRC conversion relay (6-core) 4-wire type / 6-wire type (for 520A) 1m
CA7Coaxial cable with BCN on both ends 1.5 m
CA8BNC-alligator clip cable 1.5 m
CA3150Flexible flat cable with 57F 36 pins at both ends
CN2157 series 36p connector for BCD output / set point unit
CN2357 series 24p connector for external input / output
CN35D-sub 25p connector for RS-232C

CONTACT US

Skype: fayfaywang1027

QQ: 429682794

Whatsapp: 008618016442021

E-mail: glzoncn@163.com

https://glzon.en.alibaba.com/

cel: +0086 18016442021

主站蜘蛛池模板: 午夜影院91 | 亚洲综合久久久久久888 | 毛片大片免费看 | 成人a毛片在线看免费全部播放 | 免费一看一级毛片全播放 | 国产精品福利视频 | 日本高免费观看在线播放 | 黄色毛片免费在线观看 | 欧美日韩国产综合视频在线看 | 欧美中文字幕在线观看 | 女的被到爽羞羞在线观看 | 一级黄色日本 | 午夜国产精品福利在线观看 | 性大毛片视频 | 日韩精品一区二区三区不卡 | 欧美在线中文 | 在线亚洲精品 | 国产精品女在线观看 | 日本成人黄色 | 激情在线免费视频 | 伊人网在线免费视频 | 免费观看黄色a一级录像 | 国产看片网站 | 午夜性爽视频男人的天堂在线 | 97久久精品国产精品青草 | 日本黄色站 | 91综合国产 | 久草色播 | 一二三四社区在线中文视频 | 亚洲日本一区二区三区高清在线 | 国产成人精品视频播放 | 精品免费国产一区二区三区 | 精品一区二区三区在线观看 | 在线美女 | 亚洲精品视频一区二区 | 在线三级网 | 欧美你懂的| 免费一级a毛片 | 国产精品巨乳 | 五月天在线免费视频 | 日本人视频网站一 |